Aug. 1922]
Colorimetry Report 1920-21
541
Table 2
Equivalents in Terms of Fresnels of Wave-lengths in Millimicrons
Adopted as Standard by the Illuminating Engineering Society and the Optical Society
of America 1919-1920.[1]
Wave-Lengths | Adopted Mean I. E. S | Absolute Visibility | ||
400 | 0.0004 | 0 | .27 | |
10 | .0012 | 0 | .8 | |
20 | .0040 | 2 | .7 | |
30 | .0116 | 7 | .72 | |
40 | .023 | 15 | .3 | |
450 | 0.038 | 25 | .3 | |
60 | .060 | 40 | .0 | |
70 | .091 | 60 | .7 | |
80 | .139 | 92 | .6 | |
90 | .208 | 139 | ||
500 | 0.323 | 216 | ||
10 | .484 | 322 | ||
20 | .670 | 446 | ||
30 | .836 | 587 | ||
40 | .942 | 629 | ||
550 | 0.993 | 662 | ||
10 | . 996 | 663 | ||
70 | .952 | 641 | ||
80 | .870 | 580 | ||
90 | .757 | 502 | ||
600 | 0.631 | 421 | ||
10 | .503 | 336 | ||
20 | .380 | 253 | ||
30 | .262 | 175 | ||
40 | .170 | 113 | ||
650 | 0.103 | 68 | .8 | |
60 | .059 | 39 | .3 | |
70 | .030 | 20 | .0 | |
80 | .016 | 10 | .7 | |
90 | . 0081 | 5 | .4 | |
700 | 0.0041 | 2 | .7 | |
10 | .0021 | 1 | .4 | |
20 | .0010 | 0 | .67 | |
30 | .00052 | 0 | .35 | |
40 | .00025 | 0 | .17 | |
750 | 0.00012 | 0 | .08 | |
60 | .00006 | 0 | .04 | |
Wave-Length | ||||
of maximum | 556 |
- ↑ Cf. Jour. Opt. Soc. of America, 4, p. 58; 1920.