6
Performance Evaluation of DM and DFM Filter Respirators—WORKING DRAFT 9.15.92
Table A—OSHA's 1976 Assigned Protection Factors for Particulate-Filter Respirators
Concentrations in multiples of permissible exposure limits |
Facepiece Pressure |
Permissible Respirators |
5X | - | Single use dust |
- | Quarter-mask dust | |
10X | - | Half mask dust |
- | Half- or quarter mask, fume | |
- | Half- or quarter mask, high-efficiency | |
50X | - | Full facepiece, high efficiency |
1,000X | - | Powered, high-efficiency, all enclosures |
Note: Half-mask and quarter-mask respirators should not be used if the particulate matter causes eye irritation at the use concentration.