Jump to content

Page:Niosh tb guidelines.pdf/40

From Wikisource
This page has been proofread, but needs to be validated.
IV.   Considerations in the Selection of Respirators
30

CONSIDERATION Surgical Masks
Not Certified by NIOSH
as Dust and Mist Masks
Cup-Shaped, Disposable-Mask,
Particulate Respirators (PRs)
Certified by NIOSH
Powered, HEPA-Filter, Halfmask
Respirators and
Postitive-Pressure, Air-Line, Halfmask
Respirators Certified by NIOSH
RELIABILITY OF
PROTECTIONFace-Seal Leakage
Negative-pressure operation markedly decreases the level and reliability of protection delivered by these masks.

Users cannot assure themselves that they are receiving adequate protection because there are no proven fit tests for them and they cannot be fit checked by their users.
Employers cannot assure that protection is being received b their employees.
Negative-pressure operation markedly decreases the level and reliability of protection delivered by these masks.

Users cannot assure themselves that they are receiving adequate protection because there are no proven fit tests for them and they cannot be fit checked by their users.
Employers cannot assure that protection is being received by their employees.
Positive-pressure operation markedly increases the level and reliability of protection delivered by these respirators.

Users can assure themselves that they are receiving adequate protection because these respirators can be quantitatively fit tested and fit checked by their wearers. Also, users can readily detect whether or not air is being forced into their facepieces, which indicates protection is being received.

Employers can assure that protection is being received by their employees.
Filter Leakage
Filter reliability has not been adequately evaluated against droplet nuclei.
Filter reliability has not been adequately evaluated against droplet nuclei.
HEPA filters are highly reliable against any size aerosol. Filter reliability is not an issue with air-line respirators, since no filters are used.