The essential part of this instrument consists of a plate of quartz which is cut in a special manner. When this plate is placed under tension, there is a liberation of electricity equal in amount but opposite in sign on the two sides of the plate. The plate of quartz AB (Fig. 21) is hung vertically and weights are added to the lower end. The plate is cut so that the optic axis of the crystal is horizontal and at right angles to the plane of the paper.
An image should appear at this position in the text. To use the entire page scan as a placeholder, edit this page and replace "{{missing image}}" with "{{raw image|Radio-activity.djvu/126}}". Otherwise, if you are able to provide the image then please do so. For guidance, see Wikisource:Image guidelines and Help:Adding images. |
Fig. 21.
The two faces A and B are normal to one of the binary axes (or electrical axes) of the crystal. The tension must be applied in a direction normal to the optic and electric axes. The two faces A and B are silvered, but the main portion of the plate is electrically insulated by removing a narrow strip of the silvering near the upper and lower ends of the plate. One side of the plate is connected with the electrometer and with the conductor, the rate of leak of which is to be measured. The quantity of electricity set free on one face of the plate is accurately given by
Q = 063(L/b)F,